750 kVA Cummins Diesel Generator – VTA28G6
Prime-rated 750 kVA (825 kVA standby) 50 Hz diesel generator set powered by a Cummins VTA28G6 engine. Leroy Somer alternator, DEIF SGC 420 controller, water-cooled.
750kVA Cummins VTA28G6 Diesel Generator
The 750kVA Cummins VTA28G6 is a 50 Hz diesel generating set rated at 750 kVA (600 kW) prime and 825 kVA (660 kW) standby at 1500 rpm. It pairs the Cummins VTA28G6 engine with a Leroy Somer alternator and a DEIF SGC 420 controller, with a 400V (230/400V) three-phase output. It is supplied as a complete, factory-assembled generating set with the engine, alternator and control panel mounted on a common base frame.
Cummins VTA28G6: 28-litre 12-cylinder engine with the Cummins PT self-adjusting fuel system
The VTA28G6 is a 28-litre, 12-cylinder, 40-degree Vee engine with a bore and stroke of 140 × 152 mm. The Cummins PT self-adjusting fuel system uses camshaft-actuated injectors, with a built-in dual-flyweight governor that gives overspeed protection independent of the main governor. Two Holset turbochargers are mounted on top of the engine, and the aftercooler sits in the engine coolant circuit. The limiting ambient temperature for the cooling system is 40°C. Lube oil capacity is 83 litres and the cooling system holds 182 litres.
Who is this for
Applications:
- Standby power for large commercial and industrial facilities
- Prime power for remote or weak-grid industrial sites
- Backup power for hospitals, process plants and critical loads
Industries:
- Manufacturing and process plants
- Mining and quarrying
- Oil and gas facilities
- Healthcare campuses
- Water and wastewater treatment
- Construction and infrastructure projects
Who is this for
The 750 kVA Cummins VTA28G6 is specified for large loads on 50 Hz supply where a single generating set needs to carry a whole building or process. It serves electrical engineers, project managers and procurement teams at industrial sites, large commercial and healthcare facilities, and infrastructure projects.
Typical applications
- Providing 750 kVA prime power as the main source for a site without a reliable grid connection.
- Supplying 825 kVA standby power to a facility on 50 Hz supply during a utility outage.
- Automatic mains failure (AMF) backup, with the DEIF SGC 420 starting the set and transferring load when the mains fails.
- Backing up a process plant or large building where a power cut would stop production or critical services.
- Prime power during the construction phase of an infrastructure project.
- Supporting a site during planned grid maintenance or connection upgrades.
- Running at a steady load as the primary power source for a remote operation, sized on the prime rating.
- Temporary power for events or short-term projects where the grid connection is limited.
How to install and commission
Step 1: Confirm the complete set footprint and weight with CMT Power before civil design; for reference, the VTA28G6 engine package measures 2,754 × 1,422 × 1,963 mm and weighs 2,900 kg dry. Allow at least one metre of clearance on all sides for maintenance and airflow.
Step 2: Fit vibration isolation between the base frame and the foundation, and connect the exhaust to the silencer using flexible bellows, routed away from air intakes and occupied areas. Silencer supplied: 9 dB attenuation industrial silencer; 25 dB residential silencer, delivered loose.
Step 3: Connect the fuel supply, filtration and return line, sizing the supply for at least 195 L/h, the highest published consumption for this set. Prime the fuel system fully before the first start.
Step 4: Check the alternator connection matches the site voltage (400V (230/400V), 50 Hz) and connect the output to the distribution board through a correctly rated main circuit breaker, with neutral and earth connected to the site earthing design.
Step 5: Fill the cooling system to its 182-litre capacity with a 50/50 mix of ethylene glycol and water, check all hoses, and confirm the level again at operating temperature.
Step 6: Commission the DEIF SGC 420 using DEIF Smart Connect software or the front panel: set the AMF parameters, generator and engine protection limits (under/over voltage and frequency, overload, reverse power), start/stop timers, and RS-485 Modbus, USB or CAN communication if remote monitoring is needed.
Step 7: Run a staged load test at 25%, 50%, 75% and 100% of rated load, recording voltage, frequency, oil pressure and coolant temperature at each step, and confirm load acceptance against NFPA 110.
Load sizing guidance
Add up the connected load in kW and divide by the power factor (typically 0.8) to get the kVA requirement, then add at least 20% margin so the set does not run above about 80% of its rating for long periods. Motors started direct-on-line draw several times their running current, so check the peak kVA when the largest motor starts, not just the running load. For prime power, aim to keep the load between 30% and 80% of the 750 kVA prime rating; long periods at very light load can cause wet stacking and should be avoided with load management or a load bank.
Common specification errors
- Using the standby rating for continuous duty: The 825 kVA standby rating is for emergency use during a mains failure. A set that runs every day as the main power source should be sized on its 750 kVA prime rating.
- Ordering for the wrong frequency: This set is rated at 50 Hz / 1500 rpm. A site on 60 Hz supply needs a different specification, and ratings change with speed.
- Mixing up the voltage: Confirm the site voltage (400V (230/400V)) and phase arrangement before ordering, so the alternator is connected and the AVR set correctly at the factory.
- Underestimating motor starting current: Starting several large motors at once without soft starters or variable speed drives can cause a deep voltage dip and trip the generator protection.
- Ignoring altitude and temperature derating: The cooling system’s limiting ambient temperature is 40°C. Hotter or higher sites see reduced output, so confirm the derated figures with CMT Power before specifying.
- Leaving the transfer arrangement out of the design: The DEIF SGC 420 can run automatic mains failure changeover, but only works with correctly rated and wired mains and generator breakers or a transfer switch. Include it in the electrical design from the start.
Safety and regulatory considerations
Install the set in line with ISO 8528 for generating set performance and IEC 60034 for the alternator, and follow local wiring regulations for the connection to the site supply. For emergency power systems, NFPA 110 sets the requirements for start time, load acceptance and periodic testing. Keep the exhaust away from air intakes and occupied spaces, provide adequate ventilation for cooling and combustion air, and store fuel in a bunded tank where required. The controller front panel is rated IP65. An open set installed outdoors needs a suitable enclosure for weather protection. Check the emissions rules that apply to your site, particularly for mobile or temporary use.
Maintenance schedule
| Interval | Service Task |
|---|---|
| Daily (before start) | Check engine oil level (83 L capacity), coolant level (182 L system), fuel level, battery voltage and the DEIF SGC 420 status indicators |
| Weekly | Inspect for fuel, oil and coolant leaks; check the air filter restriction indicator; run the set off load briefly if it is on standby duty |
| Engine manufacturer’s oil service interval | Change engine oil and filters; replace fuel filters and drain the water separator; inspect drive belts and hoses |
| Every 6 months | Check battery condition and charging; clean the radiator core; check alternator and control panel connections |
| Annual | Full service to the engine manufacturer’s schedule; load bank test at 75% or more of rated load; review controller protection settings |
| Every 2 years | Drain and refill the coolant; electrical insulation check on the alternator; review maintenance records for warranty compliance |
Frequently Asked Questions
Q: What is the difference between the prime power rating and the standby power rating on this generator?
The prime rating of 750 kVA (600 kW) is the output the set can supply for unlimited hours to a varying load when it is the main power source. The standby rating of 825 kVA (660 kW) is for emergency use during a mains failure, with no overload allowed. Running a set on its standby rating as a prime power source overloads the engine and shortens its life.
Q: Is this a 50 Hz or a 60 Hz generator?
This set is rated at 50 Hz, running at 1500 rpm, with a 400V (230/400V) three-phase output. The ratings above apply at 50 Hz; a 60 Hz site needs a different specification.
Q: What fuel system and governor does the VTA28G6 use?
The VTA28G6 uses the Cummins PT self-adjusting fuel system. The PT fuel system has an integral dual-flyweight governor that provides overspeed protection independent of the main governor.
Q: Which alternator is fitted, and what voltage does it supply?
The set uses a Leroy Somer alternator: single bearing, brushless and self-excited, with class H insulation. It is connected for 400V (230/400V) at 50 Hz, with voltage regulation of ±1%.
Q: What is the fuel consumption of the VTA28G6 at different loads?
For this engine the published fuel figures are on the standby curve: 195 L/h at 100% of standby, 140 L/h at 75%, 91 L/h at 50% and 50 L/h at 25%. Prime-rated consumption is not published, so use the standby figures for fuel system sizing. Fuel should meet EN 590 or an equivalent national diesel specification.
Q: What are the recommended service intervals for the VTA28G6?
Follow the engine manufacturer’s service schedule: oil and filter changes, fuel filter replacement and water separator draining at each service, with coolant replacement every two years or as the coolant type requires. Lube oil capacity is 83 litres. An annual load bank test at 75% or more of rated load helps prevent wet stacking on lightly loaded standby sets.
Q: What does the DEIF SGC 420 controller do?
The DEIF SGC 420 is a single genset controller that handles island operation, automatic mains failure (AMF), remote start/stop, cyclic running and scheduled auto exercise. It provides generator, engine and mains protection, including under/over voltage, under/over frequency, overload, reverse power, phase reversal and unbalanced load, and can monitor a site battery and shelter temperature. It communicates over RS-485 Modbus, USB and CAN, and its front panel is rated IP65.
Q: What certifications does this generator carry, and what about emissions?
The set carries: Built to comply with CE certification requirements; Designed in facilities certified to ISO 9001; Genset accepts load as per NFPA 110. The engine manufacturer’s data does not state an emissions certification for this engine. Check the emissions rules for your site, particularly for mobile or temporary use.
Q: Can CMT Power deliver and commission a 750kVA generator to a live project?
CMT Power supplies generating sets to live projects and arranges shipping and logistics internationally. For projects with a fixed date, contact the CMT Power team at enquiries@cmtpower.com or +44 (0)330 700 3377 to confirm availability, lead time and the commissioning and load testing support for your site.
Q: What warranty and options are available?
Warranty: 5 years for standby application; 2 years for prime application. Options include: Water jacket heater 220V; Sound attenuated canopy; Alternator heater; PMG kit; 4-pole main circuit breaker. Silencer: 9 dB attenuation industrial silencer; 25 dB residential silencer, delivered loose.
Have a project that needs power?
Our team can advise on the right generator for your application, capacity requirements and delivery timeline.