350 kVA Perkins Diesel Generator – 2206A-E13TAG2
In Stock

350 kVA Perkins Diesel Generator – 2206A-E13TAG2

Prime-rated 350 kVA (400 kVA standby) 50 Hz diesel generator set powered by a Perkins 2206A-E13TAG2 engine. Leroy Somer TAL-A46 alternator, Deep Sea controller, water-cooled.

Prime Power350 kVA
Standby Power400 kVA
EnginePerkins 2206A-E13TAG2
AlternatorLeroy Somer
EnclosureOpen Skid
Output Voltage400V (230/400V), 3 Phase
Quantity needed:
Talk to an Expert →

350kVA Perkins 2206A-E13TAG2 Diesel Generator

The 350kVA Perkins 2206A-E13TAG2 is a 50 Hz diesel generating set rated at 350 kVA (280 kW) prime and 400 kVA (320 kW) standby at 1500 rpm. It pairs the Perkins 2206A-E13TAG2 engine with a Leroy Somer TAL-A46 alternator and a Deep Sea controller, with a 400V (230/400V) three-phase output. It is supplied as a complete, factory-assembled generating set with the engine, alternator and control panel mounted on a common base frame.

Perkins 2206A-E13TAG2: 12.5-litre 6-cylinder vertical in-line engine

The 2206A-E13TAG2 is a 12.5-litre, 6-cylinder vertical in-line engine with a bore and stroke of 130 × 157 mm, turbocharged and air-to-air charge cooled. Mechanically actuated, electronically controlled unit injectors with full authority electronic control. Governing to ISO 8528-5 class G2 with isochronous capability. The cooling system is rated for ambient temperatures up to 50°C.

Who is this for

Applications:

  • Standby power for large commercial and industrial facilities
  • Prime power for remote or weak-grid industrial sites
  • Backup power for hospitals, process plants and critical loads

Industries:

  • Manufacturing and process plants
  • Mining and quarrying
  • Oil and gas facilities
  • Healthcare campuses
  • Water and wastewater treatment
  • Construction and infrastructure projects
Prime power
350 kVA / 280 kW
Standby power
400 kVA / 320 kW
Continuous power
Not published for this engine kVA / Not published for this engine kW
Power factor
0.8
Engine
Perkins 2206A-E13TAG2
Engine speed
1500 RPM
Alternator
Leroy Somer
Controller
Deep Sea
Cooling
Water-cooled with engine-mounted radiator. Limiting ambient temperature up to 50°C.
Output voltage
400V (230/400V), 3 Phase
Frequency
50 Hz
Phases
Three Phase
Enclosure
Open Skid
Dimensions
Engine package: 2,410 × 1,120 × 1,725 mm
Weight
1,478 kg (engine package, dry)
Certifications
CE, ISO 9001
100% load
71 L/h
75% load
54 L/h
50% load
37 L/h

Who is this for

The 350 kVA Perkins 2206A-E13TAG2 is specified for large loads on 50 Hz supply where a single generating set needs to carry a whole building or process. It serves electrical engineers, project managers and procurement teams at industrial sites, large commercial and healthcare facilities, and infrastructure projects.

Typical applications

  • Providing 350 kVA prime power as the main source for a site without a reliable grid connection.
  • Supplying 400 kVA standby power to a facility on 50 Hz supply during a utility outage.
  • Automatic mains failure (AMF) backup, with the Deep Sea starting the set and transferring load when the mains fails.
  • Backing up a process plant or large building where a power cut would stop production or critical services.
  • Prime power during the construction phase of an infrastructure project.
  • Supporting a site during planned grid maintenance or connection upgrades.
  • Running at a steady load as the primary power source for a remote operation, sized on the prime rating.
  • Temporary power for events or short-term projects where the grid connection is limited.

How to install and commission

Step 1: Confirm the complete set footprint and weight with CMT Power before civil design; for reference, the 2206A-E13TAG2 engine package measures 2,410 × 1,120 × 1,725 mm and weighs 1,478 kg dry. Allow at least one metre of clearance on all sides for maintenance and airflow.

Step 2: Fit vibration isolation between the base frame and the foundation, and connect the exhaust to the silencer using flexible bellows, routed away from air intakes and occupied areas. Silencer supplied: 9 dB attenuation industrial silencer; 25 dB residential silencer (delivered loose).

Step 3: Connect the fuel supply, filtration and return line, sizing the supply for at least 71 L/h, the highest published consumption for this set. Prime the fuel system fully before the first start.

Step 4: Check the alternator connection matches the site voltage (400V (230/400V), 50 Hz) and connect the output to the distribution board through a correctly rated main circuit breaker, with neutral and earth connected to the site earthing design.

Step 5: Fill the cooling system with a 50/50 mix of ethylene glycol and water, check all hoses, and confirm the level again at operating temperature.

Step 6: Commission the Deep Sea control module: set the automatic start parameters, engine and generator protection limits and start/stop timers, and confirm the alarms and shutdowns work.

Step 7: Run a staged load test at 25%, 50%, 75% and 100% of rated load, recording voltage, frequency, oil pressure and coolant temperature at each step.

Load sizing guidance

Add up the connected load in kW and divide by the power factor (typically 0.8) to get the kVA requirement, then add at least 20% margin so the set does not run above about 80% of its rating for long periods. Motors started direct-on-line draw several times their running current, so check the peak kVA when the largest motor starts, not just the running load. For prime power, aim to keep the load between 30% and 80% of the 350 kVA prime rating; long periods at very light load can cause wet stacking and should be avoided with load management or a load bank.

Common specification errors

  • Using the standby rating for continuous duty: The 400 kVA standby rating is for emergency use during a mains failure. A set that runs every day as the main power source should be sized on its 350 kVA prime rating.
  • Ordering for the wrong frequency: This set is rated at 50 Hz / 1500 rpm. A site on 60 Hz supply needs a different specification, and ratings change with speed.
  • Mixing up the voltage: Confirm the site voltage (400V (230/400V)) and phase arrangement before ordering, so the alternator is connected and the AVR set correctly at the factory.
  • Underestimating motor starting current: Starting several large motors at once without soft starters or variable speed drives can cause a deep voltage dip and trip the generator protection.
  • Ignoring altitude and temperature derating: The cooling system’s limiting ambient temperature is up to 50°C. Hotter or higher sites see reduced output, so confirm the derated figures with CMT Power before specifying.
  • Leaving the transfer arrangement out of the design: The Deep Sea can run automatic mains failure changeover, but only works with correctly rated and wired mains and generator breakers or a transfer switch. Include it in the electrical design from the start.

Safety and regulatory considerations

Install the set in line with ISO 8528 for generating set performance and IEC 60034 for the alternator, and follow local wiring regulations for the connection to the site supply. Keep the exhaust away from air intakes and occupied spaces, provide adequate ventilation for cooling and combustion air, and store fuel in a bunded tank where required. An open set installed outdoors needs a suitable enclosure for weather protection. Emissions: Fuel optimised. Check the rules that apply to your site, particularly for mobile or temporary use.

Maintenance schedule

Interval Service Task
Daily (before start) Check engine oil level, coolant level, fuel level, battery voltage and the Deep Sea status indicators
Weekly Inspect for fuel, oil and coolant leaks; check the air filter restriction indicator; run the set off load briefly if it is on standby duty
Engine manufacturer’s oil service interval Change engine oil and filters; replace fuel filters and drain the water separator; inspect drive belts and hoses
Every 6 months Check battery condition and charging; clean the radiator core; check alternator and control panel connections
Annual Full service to the engine manufacturer’s schedule; load bank test at 75% or more of rated load; review controller protection settings
Every 2 years Drain and refill the coolant; electrical insulation check on the alternator; review maintenance records for warranty compliance

Frequently Asked Questions

Q: What is the difference between the prime power rating and the standby power rating on this generator?

The prime rating of 350 kVA (280 kW) is the output the set can supply for unlimited hours to a varying load when it is the main power source. The standby rating of 400 kVA (320 kW) is for emergency use during a mains failure, with no overload allowed. Running a set on its standby rating as a prime power source overloads the engine and shortens its life.

Q: Is this a 50 Hz or a 60 Hz generator?

This set is rated at 50 Hz, running at 1500 rpm, with a 400V (230/400V) three-phase output. The ratings above apply at 50 Hz; a 60 Hz site needs a different specification.

Q: What fuel system and governor does the 2206A-E13TAG2 use?

The 2206A-E13TAG2 uses mechanically actuated, electronically controlled unit fuel injectors with full authority electronic control; direct injection. Governor: electronic, ISO 8528-5 class G2 with isochronous capability.

Q: Which alternator is fitted, and what voltage does it supply?

The set uses a Leroy Somer TAL-A46 alternator: single bearing, brushless and self-excited, with class H insulation, and IP23 protection. It is connected for 400V (230/400V) at 50 Hz, with voltage regulation of ±1%.

Q: What is the fuel consumption of the 2206A-E13TAG2 at different loads?

At prime rating, fuel consumption is 71 L/h at 100% load, 54 L/h at 75%, 37 L/h at 50%. Fuel should meet EN 590 or an equivalent national diesel specification.

Q: What are the recommended service intervals for the 2206A-E13TAG2?

Follow the engine manufacturer’s service schedule: oil and filter changes, fuel filter replacement and water separator draining at each service, with coolant replacement every two years or as the coolant type requires. An annual load bank test at 75% or more of rated load helps prevent wet stacking on lightly loaded standby sets.

Q: What does the Deep Sea controller do?

The Deep Sea automatic start control module monitors the engine and alternator, starts and stops the set, and shuts it down on faults such as low oil pressure, high coolant temperature and overspeed. Confirm the exact module model and its communication options with CMT Power at the quotation stage.

Q: What certifications does this generator carry, and what about emissions?

The set carries: CE certification available; Designed in facilities certified to ISO 9001. Emissions: Fuel optimised. Check the emissions rules for your site, particularly for mobile or temporary use.

Q: Can CMT Power deliver and commission a 350kVA generator to a live project?

CMT Power supplies generating sets to live projects and arranges shipping and logistics internationally. For projects with a fixed date, contact the CMT Power team at enquiries@cmtpower.com or +44 (0)330 700 3377 to confirm availability, lead time and the commissioning and load testing support for your site.

Q: What warranty and options are available?

Warranty: 5 years for standby application; 2 years for prime application. Options include: Engine: water jacket heater 220V; Enclosure: sound attenuated canopy; Alternator: alternator heater; Alternator: PMG kit; Power panel: 4-pole main circuit breaker. Silencer: 9 dB attenuation industrial silencer; 25 dB residential silencer (delivered loose).

2045 kVA Cummins Diesel Generator – QSK60G4
1500 kVA Cummins Diesel Generator – KTA50GS8
1400 kVA Cummins Diesel Generator – KTA50G8

Have a project that needs power?

Our team can advise on the right generator for your application, capacity requirements and delivery timeline.