155 kVA Cummins Diesel Generator – 6BTAA5-9G7
Prime-rated 155 kVA (170 kVA standby) 50 Hz diesel generator set powered by a Cummins 6BTAA5-9G7 engine. Leroy Somer TAL A44 alternator, DEIF SGC 420 controller, water-cooled.
155kVA Cummins 6BTAA5-9G7 Diesel Generator
The 155kVA Cummins 6BTAA5-9G7 is a 50 Hz diesel generating set rated at 155 kVA (124 kW) prime and 170 kVA (136 kW) standby at 1500 rpm, with a continuous base load rating of 104 kVA (83 kW). It pairs the Cummins 6BTAA5-9G7 engine with a Leroy Somer TAL A44 alternator and a DEIF SGC 420 controller, with a 400V (230/400V) three-phase output. It is supplied as a complete, factory-assembled generating set with the engine, alternator and control panel mounted on a common base frame.
Cummins 6BTAA5-9G7: 5.9-litre 6-cylinder in-line engine
The 6BTAA5-9G7 is a 5.9-litre, 6-cylinder in-line engine with a bore and stroke of 102 × 120 mm, turbocharged, charge air cooled. One Poly-V belt with a self-tensioning idler drives the fan, charging alternator and water pump. Fuel is delivered by an in-line Bosch A-Series pump working at high injection pressure. The limiting ambient temperature for the cooling system is 50°C. Lube oil capacity is 16.4 litres and the cooling system holds 22.1 litres.
Who is this for
Applications:
- Standby power for commercial buildings, clinics and schools
- Prime power for construction sites and remote facilities
- Backup power for pumping stations, cold stores and light industrial units
Industries:
- Commercial property and offices
- Healthcare and education
- Light manufacturing
- Water and wastewater
- Construction and infrastructure
- Agriculture and food processing
Who is this for
The 155 kVA Cummins 6BTAA5-9G7 is specified for mid-sized loads on 50 Hz supply: commercial buildings, clinics and schools, light industrial units, pumping stations and construction sites. Typical buyers are electrical contractors, facilities and estates managers, and site managers who need dependable standby or prime power without the footprint of a large industrial set.
Typical applications
- Providing 155 kVA prime power as the main source for a site without a reliable grid connection.
- Supplying 170 kVA standby power to a facility on 50 Hz supply during a utility outage.
- Automatic mains failure (AMF) backup, with the DEIF SGC 420 starting the set and transferring load when the mains fails.
- Backing up a pumping station or cold store where equipment must keep running through a power cut.
- Temporary power for a commercial fit-out or construction phase before the permanent supply is connected.
- Standby power for a clinic, school or care home.
- Base load continuous power (COP rating: 104 kVA / 83 kW) for a site running the set at constant load for unlimited hours.
- Temporary power for events or short-term projects where the grid connection is limited.
How to install and commission
Step 1: Confirm the complete set footprint and weight with CMT Power before civil design; for reference, the 6BTAA5-9G7 engine package measures 1,723 × 896 × 1,380 mm and weighs 718 kg dry. Allow at least one metre of clearance on all sides for maintenance and airflow.
Step 2: Fit vibration isolation between the base frame and the foundation, and connect the exhaust to the silencer using flexible bellows, routed away from air intakes and occupied areas. Silencer supplied: 9 dB(A) attenuation industrial silencer; 25 dB(A) residential silencer available (delivered loose).
Step 3: Connect the fuel supply, filtration and return line, sizing the supply for at least 41 L/h, the highest published consumption for this set. Prime the fuel system fully before the first start.
Step 4: Check the alternator connection matches the site voltage (400V (230/400V), 50 Hz) and connect the output to the distribution board through a correctly rated main circuit breaker, with neutral and earth connected to the site earthing design.
Step 5: Fill the cooling system to its 22.1-litre capacity with a 50/50 mix of ethylene glycol and water, check all hoses, and confirm the level again at operating temperature.
Step 6: Commission the DEIF SGC 420 using DEIF Smart Connect software or the front panel: set the AMF parameters, generator and engine protection limits (under/over voltage and frequency, overload, reverse power), start/stop timers, and RS-485 Modbus, USB or CAN communication if remote monitoring is needed.
Step 7: Run a staged load test at 25%, 50%, 75% and 100% of rated load, recording voltage, frequency, oil pressure and coolant temperature at each step.
Load sizing guidance
Add up the connected load in kW and divide by the power factor (typically 0.8) to get the kVA requirement, then add at least 20% margin so the set does not run above about 80% of its rating for long periods. Motors started direct-on-line draw several times their running current, so check the peak kVA when the largest motor starts, not just the running load. For prime power, aim to keep the load between 30% and 80% of the 155 kVA prime rating; long periods at very light load can cause wet stacking and should be avoided with load management or a load bank.
Common specification errors
- Using the standby rating for continuous duty: The 170 kVA standby rating is for emergency use during a mains failure. A set that runs every day as the main power source should be sized on its 155 kVA prime rating.
- Ordering for the wrong frequency: This set is rated at 50 Hz / 1500 rpm. A site on 60 Hz supply needs a different specification, and ratings change with speed.
- Mixing up the voltage: Confirm the site voltage (400V (230/400V)) and phase arrangement before ordering, so the alternator is connected and the AVR set correctly at the factory.
- Underestimating motor starting current: Starting several large motors at once without soft starters or variable speed drives can cause a deep voltage dip and trip the generator protection.
- Ignoring altitude and temperature derating: The cooling system’s limiting ambient temperature is 50°C. Hotter or higher sites see reduced output, so confirm the derated figures with CMT Power before specifying.
- Leaving the transfer arrangement out of the design: The DEIF SGC 420 can run automatic mains failure changeover, but only works with correctly rated and wired mains and generator breakers or a transfer switch. Include it in the electrical design from the start.
Safety and regulatory considerations
Install the set in line with ISO 8528 for generating set performance and IEC 60034 for the alternator, and follow local wiring regulations for the connection to the site supply. Keep the exhaust away from air intakes and occupied spaces, provide adequate ventilation for cooling and combustion air, and store fuel in a bunded tank where required. The controller front panel is rated IP65. An open set installed outdoors needs a suitable enclosure for weather protection. Check the emissions rules that apply to your site, particularly for mobile or temporary use.
Maintenance schedule
| Interval | Service Task |
|---|---|
| Daily (before start) | Check engine oil level (16.4 L capacity), coolant level (22.1 L system), fuel level, battery voltage and the DEIF SGC 420 status indicators |
| Weekly | Inspect for fuel, oil and coolant leaks; check the air filter restriction indicator; run the set off load briefly if it is on standby duty |
| Engine manufacturer’s oil service interval | Change engine oil and filters; replace fuel filters and drain the water separator; inspect drive belts and hoses |
| Every 6 months | Check battery condition and charging; clean the radiator core; check alternator and control panel connections |
| Annual | Full service to the engine manufacturer’s schedule; load bank test at 75% or more of rated load; review controller protection settings |
| Every 2 years | Drain and refill the coolant; electrical insulation check on the alternator; review maintenance records for warranty compliance |
Frequently Asked Questions
Q: What is the difference between the prime power rating and the standby power rating on this generator?
The prime rating of 155 kVA (124 kW) is the output the set can supply for unlimited hours to a varying load when it is the main power source. The standby rating of 170 kVA (136 kW) is for emergency use during a mains failure, with no overload allowed. The base load (continuous) rating of 104 kVA (83 kW) applies when the set runs at a constant load for unlimited hours. Running a set on its standby rating as a prime power source overloads the engine and shortens its life.
Q: Is this a 50 Hz or a 60 Hz generator?
This set is rated at 50 Hz, running at 1500 rpm, with a 400V (230/400V) three-phase output. The ratings above apply at 50 Hz; a 60 Hz site needs a different specification.
Q: What fuel system and governor does the 6BTAA5-9G7 use?
The 6BTAA5-9G7 uses the Bosch mechanical (in-line Bosch A-Series injection pump). The engine manufacturer’s data for this model does not state the governor type, so confirm it with CMT Power if precise frequency control is a requirement.
Q: Which alternator is fitted, and what voltage does it supply?
The set uses a Leroy Somer TAL A44 alternator: single bearing, brushless and self-excited, with class H insulation. It is connected for 400V (230/400V) at 50 Hz, with voltage regulation of ±1%.
Q: What is the fuel consumption of the 6BTAA5-9G7 at different loads?
At prime rating, fuel consumption is 37 L/h at 100% load, 29 L/h at 75%, 19 L/h at 50% and 9 L/h at 25%. At full standby rating it is 41 L/h. At the continuous rating it is 26 L/h. Fuel should meet EN 590 or an equivalent national diesel specification.
Q: What are the recommended service intervals for the 6BTAA5-9G7?
Follow the engine manufacturer’s service schedule: oil and filter changes, fuel filter replacement and water separator draining at each service, with coolant replacement every two years or as the coolant type requires. Lube oil capacity is 16.4 litres. An annual load bank test at 75% or more of rated load helps prevent wet stacking on lightly loaded standby sets.
Q: What does the DEIF SGC 420 controller do?
The DEIF SGC 420 is a single genset controller that handles island operation, automatic mains failure (AMF), remote start/stop, cyclic running and scheduled auto exercise. It provides generator, engine and mains protection, including under/over voltage, under/over frequency, overload, reverse power, phase reversal and unbalanced load, and can monitor a site battery and shelter temperature. It communicates over RS-485 Modbus, USB and CAN, and its front panel is rated IP65.
Q: What certifications does this generator carry, and what about emissions?
The set carries: Engine designed in ISO 9001 certified facilities; manufactured in ISO 9001 or ISO 9002 certified facilities; Engine designed and tested to meet EU product safety regulations; CE certification available. The engine manufacturer’s data does not state an emissions certification for this engine. Check the emissions rules for your site, particularly for mobile or temporary use.
Q: Can CMT Power deliver and commission a 155kVA generator to a live project?
CMT Power supplies generating sets to live projects and arranges shipping and logistics internationally. For projects with a fixed date, contact the CMT Power team at enquiries@cmtpower.com or +44 (0)330 700 3377 to confirm availability, lead time and the commissioning and load testing support for your site.
Q: What warranty and options are available?
Warranty: 5 years for standby application; 2 years for prime application. Options include: Engine water jacket heater 220V; Sound attenuated canopy; Alternator heater; PMG kit. Silencer: 9 dB(A) attenuation industrial silencer; 25 dB(A) residential silencer available (delivered loose).
Have a project that needs power?
Our team can advise on the right generator for your application, capacity requirements and delivery timeline.